Electronic stethoscope in the diagnosis of orthostatic tremor

J. Tashiro, H. Otsuka, M. Hirotani, S. Hamada, H. Soma, M. Nonaka, S. Honma, K. Hamada, A. Takei, F. Moriwaka, K. Tashiro (Sapporo, Japan)

Meeting: 2017 International Congress

Abstract Number: 772

Keywords: Orthostatic tremor (also see Tremors), Tremors: Clinical features

Session Information

Date: Tuesday, June 6, 2017

Session Title: Tremor

Session Time: 1:45pm-3:15pm

Location: Exhibit Hall C

Objective: To demonstrate the usefulness of electronic stethoscope (ES) in making diagnosis of orthostatic tremor (OT).

Background: OT is a rare disorder first reported in the English literature by Heilman in 1984 and characterized by leg tremor and subjective unsteadiness only on standing, absent when sitting or lying, and improved by walking or leaning. The tremor cannot be reliably seen or palpated (1), and the diagnosis can be confirmed only by electromyography (EMG) recordings with a typical 13-18 Hz pattern (2). In 1995, Brown reported a new clinical sign for OT. It is a sound similar to the noise of a distant helicopter heard with a stethoscope (1). Recently, several models of ES have become commercially available and the recorded sound of auscultation can be transferred to a PC and immediately visualized. It would be useful if the diagnosis of OT could be confirmed by the findings of ES, especially in institutions where surface EMG is not easily available.

Methods: In a case with confirmed OT, the sound of leg muscles was recorded by ES (3M™ Littmann® Electronic Stethoscope Model 3200, 3M). The audio files were transferred via Bluetooth® to a PC (MacBook Pro®, Apple Inc.) and visualized by 3M™ Littmann® Stethassist™ software for analysis. The frequency and waveform of the muscle sound were compared with those of surface EMG of the same case.

Results: A female in her fifth decade noticed tremor in her left hand and both legs and unsteadiness when waiting in a queue 7 years before. Her symptoms appeared only when standing still, alleviated on leaning, and disappeared on walking. On examination, postural tremor was found in her arms, and the fine tremor in leg muscles was visible and palpable on standing with intermittent myoclonic movement. The ‘helicopter sign’ was heard by auscultation. Surface EMG revealed 16 Hz discharges and the diagnosis of OT was confirmed. Clonazepam was effective and the frequency of surface EMG was reduced to about 14 Hz. The sound of leg muscles recorded by ES was visualized and its frequency of the waveform was determined to be about 14 Hz.

Conclusions: The findings of unique ‘helicopter sign’ for OT recorded and visualized using ES and analyzing software become comparable with those of surface EMG. Their frequencies are considered to be identical, which suggests that the diagnosis of OT may be confirmed by ES instead of surface EMG.

References: 1. Brown P. New clinical sign for orthostatic tremor. Lancet 1995;346:306-307.

2. Deuschl G, Bain P, Brin M, and an Ad Hoc Scientific Committee. Consensus statement of the Movement Disorder Society on Tremor. Mov Disord 1998;13(Suppl 3):2-23

To cite this abstract in AMA style:

J. Tashiro, H. Otsuka, M. Hirotani, S. Hamada, H. Soma, M. Nonaka, S. Honma, K. Hamada, A. Takei, F. Moriwaka, K. Tashiro. Electronic stethoscope in the diagnosis of orthostatic tremor [abstract]. Mov Disord. 2017; 32 (suppl 2). https://www.mdsabstracts.org/abstract/electronic-stethoscope-in-the-diagnosis-of-orthostatic-tremor/. Accessed June 15, 2025.
  • Tweet
  • Click to email a link to a friend (Opens in new window) Email
  • Click to print (Opens in new window) Print

« Back to 2017 International Congress

MDS Abstracts - https://www.mdsabstracts.org/abstract/electronic-stethoscope-in-the-diagnosis-of-orthostatic-tremor/

Most Viewed Abstracts

  • This Week
  • This Month
  • All Time
  • Covid vaccine induced parkinsonism and cognitive dysfunction
  • Life expectancy with and without Parkinson’s disease in the general population
  • What is the appropriate sleep position for Parkinson's disease patients with orthostatic hypotension in the morning?
  • Patients with Essential Tremor Live Longer than their Relatives
  • Increased Risks of Botulinum Toxin Injection in Patients with Hypermobility Ehlers Danlos Syndrome: A Case Series
  • Covid vaccine induced parkinsonism and cognitive dysfunction
  • What is the appropriate sleep position for Parkinson's disease patients with orthostatic hypotension in the morning?
  • Life expectancy with and without Parkinson’s disease in the general population
  • The hardest symptoms that bother patients with Parkinson's disease
  • An Apparent Cluster of Parkinson's Disease (PD) in a Golf Community
  • Effect of marijuana on Essential Tremor: A case report
  • Increased Risks of Botulinum Toxin Injection in Patients with Hypermobility Ehlers Danlos Syndrome: A Case Series
  • Covid vaccine induced parkinsonism and cognitive dysfunction
  • Estimation of the 2020 Global Population of Parkinson’s Disease (PD)
  • Patients with Essential Tremor Live Longer than their Relatives
  • Help & Support
  • About Us
  • Cookies & Privacy
  • Wiley Job Network
  • Terms & Conditions
  • Advertisers & Agents
Copyright © 2025 International Parkinson and Movement Disorder Society. All Rights Reserved.
Wiley