Reliability of Continuous Parkinson’s Assessment Using Wearables

D. Heldman, E. Urrea Mendoza, N. Mennucci, C. Zimmerman, J. Giuffrida, A. Hadley, Z. Mari, M. Burack, I. Itin, F. Revilla (Cleveland, OH, USA)

Meeting: 2017 International Congress

Abstract Number: 655

Keywords: Bradykinesia, Dyskinesias, Tremors: Clinical features

Session Information

Date: Tuesday, June 6, 2017

Session Title: Technology

Session Time: 1:45pm-3:15pm

Location: Exhibit Hall C

Objective: To evaluate test-retest reliability and determine the optimal number of days of use for wearable sensors and a mobile software app to continuously and objectively assess Parkinson’s disease (PD) during activities of daily living.  

Background: Consumer wearables linked with smartphone apps are becoming increasingly common to assess PD. Determining test-retest reliability and providing guidance for balancing patient burden and number of days of use required to obtain clinically significant results is essential for validation.

Methods: Thirteen adults (Age 53-74) with PD and at least two hours of OFF time and/or one hour of troublesome dyskinesia participated in a 5-month study. Participants were trained to don motion sensors on the wrist and ankle and use a smartphone app to start/stop data collection. Participants were instructed to use the system throughout the waking day for blocks of four consecutive days during the first week, third week, and each of months 2-5. At the end of each day of use, participants removed the sensors for wireless recharging and data upload to a server for processing into metrics quantifying tremor, dyskinesia, slowness, and gait throughout the day using previously validated algorithms. Intraclass correlation (ICC) and minimal detectable change (MDC) were calculated between weeks 1 and 3 when averaging 1, 2, 3, and 4 days of collected data.

Results: For each block a participant used the device for at least one day, compliance for 2, 3, and 4 days was 100%, 92%, and 84%, respectively. Average ICCs were 0.74, 0.80, 0.88, and 0.94 when including 1, 2, 3, and 4 days of data, respectively, while average MDCs were 22.4, 16.9, 13.2, and 10.1 (percent full scale).

Conclusions: Reliability and sensitivity improved with increasing number of days of use; however, so did patient burden. Three days of use may provide an optimal compromise to minimize patient burden without sacrificing reliability. 

References: A version of this abstract was submitted to be presented at the American Academy of Neurology 2017 Annual Meeting. 

To cite this abstract in AMA style:

D. Heldman, E. Urrea Mendoza, N. Mennucci, C. Zimmerman, J. Giuffrida, A. Hadley, Z. Mari, M. Burack, I. Itin, F. Revilla. Reliability of Continuous Parkinson’s Assessment Using Wearables [abstract]. Mov Disord. 2017; 32 (suppl 2). https://www.mdsabstracts.org/abstract/reliability-of-continuous-parkinsons-assessment-using-wearables/. Accessed June 14, 2025.
  • Tweet
  • Click to email a link to a friend (Opens in new window) Email
  • Click to print (Opens in new window) Print

« Back to 2017 International Congress

MDS Abstracts - https://www.mdsabstracts.org/abstract/reliability-of-continuous-parkinsons-assessment-using-wearables/

Most Viewed Abstracts

  • This Week
  • This Month
  • All Time
  • Humor processing is affected by Parkinson’s disease and levodopa
      • Help & Support
      • About Us
      • Cookies & Privacy
      • Wiley Job Network
      • Terms & Conditions
      • Advertisers & Agents
      Copyright © 2025 International Parkinson and Movement Disorder Society. All Rights Reserved.
      Wiley